OEM#: ECT/FL-DLX/PNew OEM Original Outright
FLANGELESS DELUXE JASZCZAK PHANTOM by Data Spectrum Corporation
Your price:
$3,474.93 each

OEM#: ECT/FL-DLX/PFLANGELESS DELUXE JASZCZAK PHANTOM by Data Spectrum Corporation
New OEM Original Outright
Your price:
$3,474.93 each
Asset Information
Are you an existing customer? Sign in to access your account.
ADD TO LIST
Product Overview
- Deluxe ECT phantom without protruding flange
Applications:
- For use with high spatial resolution SPECT and PET systems
- System performance evaluation (collimator, artifacts, calibration, reconstruction parameters)
- Acceptance testing
- Routine quality assurance and control
- Evaluation of center-of-rotation error
- Evaluation of non-uniformity artifact
- Evaluation of changes of radius-of-rotation on spatial resolution
- Evaluation of reconstruction filters on spatial resolution
- Evaluation of attenuation and scatter compensation
- Research
- ACR recommended phantom
Technical Specs
P/N: ECT/FL-DLX/P Key Specs
Item
FLANGELESS DELUXE JASZCZAK PHANTOM
OEM
Data Spectrum Corporation
OEM #
ECT/FL-DLX/P
Condition
New OEM Original
Returnable
No
Warranty
Mfr Warranty
Center Sphere Base Plate Height
5 IN
Cylinder Inside Diameter
8 IN
Cylinder Wall Thickness
0.25 IN
Rod Diameter
4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 MM
Rod Height
3.4 IN
Solid Sphere Diameter
9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 MM
- Deluxe ECT phantom without protruding flange
Applications:
- For use with high spatial resolution SPECT and PET systems
- System performance evaluation (collimator, artifacts, calibration, reconstruction parameters)
- Acceptance testing
- Routine quality assurance and control
- Evaluation of center-of-rotation error
- Evaluation of non-uniformity artifact
- Evaluation of changes of radius-of-rotation on spatial resolution
- Evaluation of reconstruction filters on spatial resolution
- Evaluation of attenuation and scatter compensation
- Research
- ACR recommended phantom
Product Overview
- Deluxe ECT phantom without protruding flange
Applications:
- For use with high spatial resolution SPECT and PET systems
- System performance evaluation (collimator, artifacts, calibration, reconstruction parameters)
- Acceptance testing
- Routine quality assurance and control
- Evaluation of center-of-rotation error
- Evaluation of non-uniformity artifact
- Evaluation of changes of radius-of-rotation on spatial resolution
- Evaluation of reconstruction filters on spatial resolution
- Evaluation of attenuation and scatter compensation
- Research
- ACR recommended phantom
Technical Specs
P/N: ECT/FL-DLX/P Key Specs
Item
FLANGELESS DELUXE JASZCZAK PHANTOM
OEM
Data Spectrum Corporation
OEM #
ECT/FL-DLX/P
Condition
New OEM Original
Returnable
No
Warranty
Mfr Warranty
Center Sphere Base Plate Height
5 IN
Cylinder Inside Diameter
8 IN
Cylinder Wall Thickness
0.25 IN
Rod Diameter
4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 MM
Rod Height
3.4 IN
Solid Sphere Diameter
9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 MM
- Deluxe ECT phantom without protruding flange
Applications:
- For use with high spatial resolution SPECT and PET systems
- System performance evaluation (collimator, artifacts, calibration, reconstruction parameters)
- Acceptance testing
- Routine quality assurance and control
- Evaluation of center-of-rotation error
- Evaluation of non-uniformity artifact
- Evaluation of changes of radius-of-rotation on spatial resolution
- Evaluation of reconstruction filters on spatial resolution
- Evaluation of attenuation and scatter compensation
- Research
- ACR recommended phantom
Product Overview
- Deluxe ECT phantom without protruding flange
Applications:
- For use with high spatial resolution SPECT and PET systems
- System performance evaluation (collimator, artifacts, calibration, reconstruction parameters)
- Acceptance testing
- Routine quality assurance and control
- Evaluation of center-of-rotation error
- Evaluation of non-uniformity artifact
- Evaluation of changes of radius-of-rotation on spatial resolution
- Evaluation of reconstruction filters on spatial resolution
- Evaluation of attenuation and scatter compensation
- Research
- ACR recommended phantom
Technical Specs
P/N: ECT/FL-DLX/P Key Specs
Item
FLANGELESS DELUXE JASZCZAK PHANTOM
OEM
Data Spectrum Corporation
OEM #
ECT/FL-DLX/P
Condition
New OEM Original
Returnable
No
Warranty
Mfr Warranty
Center Sphere Base Plate Height
5 IN
Cylinder Inside Diameter
8 IN
Cylinder Wall Thickness
0.25 IN
Rod Diameter
4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 MM
Rod Height
3.4 IN
Solid Sphere Diameter
9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 MM
- Deluxe ECT phantom without protruding flange
Applications:
- For use with high spatial resolution SPECT and PET systems
- System performance evaluation (collimator, artifacts, calibration, reconstruction parameters)
- Acceptance testing
- Routine quality assurance and control
- Evaluation of center-of-rotation error
- Evaluation of non-uniformity artifact
- Evaluation of changes of radius-of-rotation on spatial resolution
- Evaluation of reconstruction filters on spatial resolution
- Evaluation of attenuation and scatter compensation
- Research
- ACR recommended phantom